US Core Testing Guide - Local Development build (v3.1.1-1). See the Directory of published versions
Active as of 2023-08-25 |
{
"resourceType" : "TestScript",
"id" : "Allergyreadvalidatejson",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: TestScript</b><a name=\"Allergyreadvalidatejson\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource TestScript "Allergyreadvalidatejson" </p></div><p><b>url</b>: <code>http://hl7.org/fhir/us/core-tg/TestScript/Allergyreadvalidatejson</code></p><p><b>version</b>: 3.1.1-1</p><p><b>name</b>: Allergyreadvalidatejson</p><p><b>title</b>: HL7 FHIR R4 TestScript Read Validate US Core AllergyIntolerance JSON</p><p><b>status</b>: active</p><p><b>date</b>: 2023-08-25</p><p><b>publisher</b>: HL7 FHIR Infrastructure WG</p><p><b>contact</b>: HL7 FHIR Infrastructure WG: <a href=\"https://hl7.org/Special/committees/fiwg\">https://hl7.org/Special/committees/fiwg</a>, Richard Ettema: <a href=\"mailto:mailto:richard.ettema@aegis.net\">mailto:richard.ettema@aegis.net</a></p><p><b>description</b>: TestScript to test USCoreAllergyIntolerance resource read and profile validation using #json format</p><p><b>jurisdiction</b>: United States of America <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.0.0/CodeSystem-ISO3166Part1.html\">ISO 3166-1 Codes for the representation of names of countries and their subdivisions — Part 1: Country code</a>#US)</span></p><p><b>copyright</b>: (c) Health Level 7 (HL7) International 2023</p><h3>Origins</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Index</b></td><td><b>Profile</b></td></tr><tr><td style=\"display: none\">*</td><td>1</td><td>FHIR Client (Details: http://terminology.hl7.org/CodeSystem/testscript-profile-origin-types code FHIR-Client = 'FHIR Client', stated as 'null')</td></tr></table><h3>Destinations</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Index</b></td><td><b>Profile</b></td></tr><tr><td style=\"display: none\">*</td><td>1</td><td>FHIR Server (Details: http://terminology.hl7.org/CodeSystem/testscript-profile-destination-types code FHIR-Server = 'FHIR Server', stated as 'null')</td></tr></table><p><b>profile</b>: <a href=\"http://hl7.org/fhir/us/core/StructureDefinition/us-core-allergyintolerance\">http://hl7.org/fhir/us/core/StructureDefinition/us-core-allergyintolerance</a> "USCoreAllergyIntolerance"</p><blockquote><p><b>test</b></p><blockquote><p><b>id</b></p>ReadValidate</blockquote><p><b>name</b>: ReadValidate</p><p><b>description</b>: Test USCoreAllergyIntolerance resource read on destination server and assert returned resource passes validation</p><blockquote><p><b>action</b></p><h3>Operations</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Type</b></td><td><b>Resource</b></td><td><b>Description</b></td><td><b>Accept</b></td><td><b>ContentType</b></td><td><b>Destination</b></td><td><b>EncodeRequestUrl</b></td><td><b>Origin</b></td><td><b>Params</b></td></tr><tr><td style=\"display: none\">*</td><td>Read (Details: http://terminology.hl7.org/CodeSystem/testscript-operation-codes code read = 'Read', stated as 'null')</td><td>AllergyIntolerance</td><td>ResourceRead</td><td>json</td><td>json</td><td>1</td><td>true</td><td>1</td><td>/example</td></tr></table></blockquote><blockquote><p><b>action</b></p><h3>Asserts</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Description</b></td><td><b>Direction</b></td><td><b>ResponseCode</b></td><td><b>WarningOnly</b></td></tr><tr><td style=\"display: none\">*</td><td>Confirm that the returned response code is 200 OK.</td><td>response</td><td>200</td><td>false</td></tr></table></blockquote><blockquote><p><b>action</b></p><h3>Asserts</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Description</b></td><td><b>Direction</b></td><td><b>Resource</b></td><td><b>WarningOnly</b></td></tr><tr><td style=\"display: none\">*</td><td>Confirm that the returned response payload is the specified resource.</td><td>response</td><td>AllergyIntolerance</td><td>false</td></tr></table></blockquote><blockquote><p><b>action</b></p><h3>Asserts</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Description</b></td><td><b>Direction</b></td><td><b>ValidateProfileId</b></td><td><b>WarningOnly</b></td></tr><tr><td style=\"display: none\">*</td><td>Confirm that the returned resource conforms to the specified profile.</td><td>response</td><td>USCoreAllergyProfile</td><td>false</td></tr></table></blockquote></blockquote></div>"
},
"url" : "http://hl7.org/fhir/us/core-tg/TestScript/Allergyreadvalidatejson",
"version" : "3.1.1-1",
"name" : "Allergyreadvalidatejson",
"title" : "HL7 FHIR R4 TestScript Read Validate US Core AllergyIntolerance JSON",
"status" : "active",
"date" : "2023-08-25",
"publisher" : "HL7 FHIR Infrastructure WG",
"contact" : [
{
"name" : "HL7 FHIR Infrastructure WG",
"telecom" : [
{
"system" : "url",
"value" : "https://hl7.org/Special/committees/fiwg"
}
]
},
{
"name" : "Richard Ettema",
"telecom" : [
{
"system" : "email",
"value" : "mailto:richard.ettema@aegis.net"
}
]
}
],
"description" : "TestScript to test USCoreAllergyIntolerance resource read and profile validation using #json format",
"jurisdiction" : [
{
"coding" : [
{
"system" : "urn:iso:std:iso:3166",
"code" : "US"
}
]
}
],
"copyright" : "(c) Health Level 7 (HL7) International 2023",
"origin" : [
{
"index" : 1,
"profile" : {
"system" : "http://terminology.hl7.org/CodeSystem/testscript-profile-origin-types",
"code" : "FHIR-Client"
}
}
],
"destination" : [
{
"index" : 1,
"profile" : {
"system" : "http://terminology.hl7.org/CodeSystem/testscript-profile-destination-types",
"code" : "FHIR-Server"
}
}
],
"profile" : [
{
"id" : "USCoreAllergyProfile",
"reference" : "http://hl7.org/fhir/us/core/StructureDefinition/us-core-allergyintolerance"
}
],
"test" : [
{
"id" : "ReadValidate",
"name" : "ReadValidate",
"description" : "Test USCoreAllergyIntolerance resource read on destination server and assert returned resource passes validation",
"action" : [
{
"operation" : {
"type" : {
"system" : "http://terminology.hl7.org/CodeSystem/testscript-operation-codes",
"code" : "read"
},
"resource" : "AllergyIntolerance",
"description" : "ResourceRead",
"accept" : "json",
"contentType" : "json",
"destination" : 1,
"encodeRequestUrl" : true,
"origin" : 1,
"params" : "/example"
}
},
{
"assert" : {
"description" : "Confirm that the returned response code is 200 OK.",
"direction" : "response",
"responseCode" : "200",
"warningOnly" : false
}
},
{
"assert" : {
"description" : "Confirm that the returned response payload is the specified resource.",
"direction" : "response",
"resource" : "AllergyIntolerance",
"warningOnly" : false
}
},
{
"assert" : {
"description" : "Confirm that the returned resource conforms to the specified profile.",
"direction" : "response",
"validateProfileId" : "USCoreAllergyProfile",
"warningOnly" : false
}
}
]
}
]
}
IG © 2023+ HL7 FHIR Infrastructure WG. Package hl7.fhir.us.core-tg#3.1.1-1 based on FHIR 4.0.1. Generated 2023-09-06
Links: Table of Contents |
QA Report
| Version History |
|
Propose a change